FXMQ-MA | Daikin

FXMQ200MAVE FXMQ250MAVE

Sound pressure level

Cooling

At low fan speed

dBA

45

45

 

 

At high fan speed

dBA

48

48

Standard Accessories

Installation and operation manual

Installation and operation manual

Installation and operation manual

 

Connection pipes

Connection pipes

Connection pipes

 

Sealing pads

Sealing pads

Sealing pads

 

Clamps

Clamps

Clamps

 

Screws

Screws

Screws

Refrigerant

Type

 

R-410A

R-410A

Power input – 50Hz

Cooling

At high fan speed

kW

1.294

1.465

 

Heating

At high fan speed

kW

1.294

1.465

Cooling capacity

Total capacity

At high fan speed

kW

22.4 (1)

28.0 (1)

Piping connections

Liquid

OD

mm

9.52

9.52

 

 

Type

 

Flare connection

Flare connection

 

Gas

OD

mm

19.1

22.2

 

 

Type

 

Braze connection

Braze connection

 

Drain

 

PS1B

PS1B

Dimensions

Unit

Width

mm

1,380

1,380

 

 

Depth

mm

1,100

1,100

 

 

Height

mm

470

470

Casing

Material

 

Galvanised steel plate

Galvanised steel plate

Weight

Unit

kg

137

137

Fan

External static pressure – 50Hz

High

Pa

221 (4)

270 (4)

 

External static pressure – 60Hz

High

Pa

270

270

 

Air flow rate – 50Hz

Cooling

At high fan speed

m³/min

58

72

 

 

 

At low fan speed

m³/min

50

62

 

Air flow rate – 60Hz

Cooling

High

m³/min

58

72

 

 

 

Low

m³/min

50

62

Heating capacity

Total capacity

At high fan speed

kW

25.0 (2)

31.5 (2)

Current – 50Hz

Maximum fuse amps (MFA)

A

15

15

Power supply

Phase

 

1~

1~

 

Name

 

VE

VE

 

Frequency

Hz

50/60

50/60

 

Voltage

V

220-240/220

220-240/220

Notes

(1) – Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal)

(1) – Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal)

 

(2) – Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal)

(2) – Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal)

 

(3) – Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.

(3) – Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.

 

(4) – The external static pressure is changeable: change the connectors inside the electrical box, this pressure means: High static pressure – Standard

(4) – The external static pressure is changeable: change the connectors inside the electrical box, this pressure means: High static pressure – Standard

 

(5) – Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its dust collection efficiency (gravity method) 50% and more.

(5) – Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its dust collection efficiency (gravity method) 50% and more.

 

(6) – Sound pressure levels are measured at 220V.

(6) – Sound pressure levels are measured at 220V.

 

(7) – Reference acoustic pressure 0 dB = 20 Pa.

(7) – Reference acoustic pressure 0 dB = 20 Pa.

 

(8) – Sound values are measured in an anechoic room.

(8) – Sound values are measured in an anechoic room.

 

(9) – Operation sound differs with operation and ambient conditions

(9) – Operation sound differs with operation and ambient conditions

 

(10) – Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.

(10) – Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.

 

(11) – Maximum allowable voltage range variation between phases is 2%.

(11) – Maximum allowable voltage range variation between phases is 2%.

 

(12) – MCA/MFA: MCA = 1.25 x FLA

(12) – MCA/MFA: MCA = 1.25 x FLA

 

(13) – MFA ≤ 4 x FLA

(13) – MFA ≤ 4 x FLA

 

(14) – Next lower standard fuse rating minimum 15A

(14) – Next lower standard fuse rating minimum 15A

 

(15) – Select wire size based on the value of MCA

(15) – Select wire size based on the value of MCA

 

(16) – Instead of a fuse, use a circuit breaker

(16) – Instead of a fuse, use a circuit breaker